您好,歡迎來到北京明尼克分析儀器設(shè)備中心網(wǎng)站!
更新時間: 2017-07-04
產(chǎn)品型號:
所 在 地: 北京市朝陽區(qū)望京西園222號星源國際D座1503室
產(chǎn)品特點: High capacity and loadability give exceptionally symmetric peaks; ideal for volatile hydrocarbon separations at percent levels, as well as impurity analyses at ppm concentrations.
共創(chuàng)共贏
產(chǎn)品概述
Rt®-Alumina BOND/Na2SO4 Columns (fused silica PLOT)
(Na2SO4 deactivation)
Guaranteed Reproducibility
Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene.
With our new technology, both Na2SO4 and KCl are available with the Rt®-Alumina BOND columns.
Similar Phase(s):
GS-Alumina, HP PLOT S, HP PLOT M, Alumina-PLOT, AT-Alumina, CP-Al2O3/NA2SO4
catalog # | length | id | df | units | |
19757 | | | 5μm | ea. | |
19758 | | | 5μm | ea. | |
19755 | | | 10μm | ea. | |
19756 | | | 10μm | ea. | |
Showing 1 to 4 of 4 entries
1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to
Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.
Acetylene/propadiene elute after butanes (impurities in acetylene/propadiene).
Best separation for butene isomers (impurities in butene streams).
Methyl acetylene elutes after 1,3-butadiene.
Cyclopropane (impurity in propylene) elutes well before propylene.
北京明尼克分析儀器設(shè)備中心
聯(lián)系人:薛海玲 電話:010-84723211 郵箱:xuehail@163.com 總部地址:北京市朝陽區(qū)望京西園222號星源國際D座1503室
研發(fā)中心:北京市平谷區(qū)中關(guān)村科技園區(qū)興谷A區(qū)平和街39號院(聯(lián)東U谷)22號樓C區(qū)
版權(quán)所有 © 2024 北京明尼克分析儀器設(shè)備中心 總流量:978122 備案號:京ICP備10037012號-2
管理登陸 網(wǎng)站地圖 技術(shù)支持:化工儀器網(wǎng)