您好,歡迎來到北京明尼克分析儀器設(shè)備中心網(wǎng)站!
更新時(shí)間: 2017-07-05
產(chǎn)品型號:
所 在 地: 北京市朝陽區(qū)望京西園222號星源國際D座1503室
產(chǎn)品特點(diǎn): Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures.
共創(chuàng)共贏
產(chǎn)品概述
Rt®-Alumina BOND/CFC Columns (fused silica PLOT)
Improved inertness for halogenated compounds.
Highly selective alumina-based column, separates most CFCs.
High retention and capacity for CFCs.
Product Name:
Rt-Alumina BOND/CFC
Temp. Limits:
to
Length:
Internal Diameter:
df (µm):
10μm
1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to
Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.
Improved inertness for halogenated compounds.
Highly selective alumina-based column, separates most CFCs.
High retention and capacity for CFCs.
The alumina adsorbent is ideal for retaining halogenated compounds, especially CFC (chlorinated flourocarbons, freons). It offers high selectivity, allowing a wide range of CFC isomers to be resolved at above ambient temperatures. The Rt®-Alumina BOND/CFC column is thoroughly deactivated to reduce the reactivity of alumina. Even though there is still some residual reactivity for some mono- or di-substituted halogenated hydrocarbons, the majority of these compounds can be accuray quantified from main stream processes or in impurity analyses.
北京明尼克分析儀器設(shè)備中心
聯(lián)系人:薛海玲 電話:010-84723211 郵箱:xuehail@163.com 總部地址:北京市朝陽區(qū)望京西園222號星源國際D座1503室
研發(fā)中心:北京市平谷區(qū)中關(guān)村科技園區(qū)興谷A區(qū)平和街39號院(聯(lián)東U谷)22號樓C區(qū)
版權(quán)所有 © 2024 北京明尼克分析儀器設(shè)備中心 總流量:978122 備案號:京ICP備10037012號-2
管理登陸 網(wǎng)站地圖 技術(shù)支持:化工儀器網(wǎng)